Air conditioner operating and display unit -J255
 
 
Measured value block 001
 
Display zone 1
 
Measured control current for air conditioning system compressor regulating valve -N280 (in Amperes)
J  Readout 0.05 A
- Compressor off.
J Readout 0.30 A to 0.65 A
- Compressor in loop control mode
 
Display zone 2
 
Duty factor for operation of compressor regulating valve -N280 (in %)
J Readout 0 percent
- Compressor off.
J Readout 30....40 percent to 100 percent
- Compressor in loop control mode
 
Display zone 3
 
Duty factor for pressure signal from high-pressure sender -G65 (in percent)
J Readout 0 percent to 5 percent
- Open circuit in wiring/voltage supply or earth connection                                              
- High-pressure sender -G65 defective
J Readout 5 percent to 12 percent
- Pressure in refrigerant circuit too low (system empty)
- High-pressure sender -G65 defective
J Readout 12 percent to 87.5 percent
- Pressure in refrigerant circuit within permissible range
J Readout above 87.5...90 percent
- Pressure in refrigerant circuit too high
- Activation of radiator fan not OK
- High-pressure sender -G65 defective
- Radiator and/or condenser dirt-clogged
- Fault in refrigerant circuit
J Readout 90....100 percent
- Short
- Open circuit in voltage supply or earth connection                                              
- High-pressure sender -G65 defective
 
Display zone 4
 
Pressure in refrigerant circuit (in bar absolute pressure)
J Readout below 2.6 bar
- Pressure in refrigerant circuit too low (system empty)
- High-pressure sender -G65 defective
J Readout 2.6 bar to 29 bar
- Pressure in refrigerant circuit within permissible range
J Readout above 29 bar (even for a short time)
- Pressure in refrigerant circuit too high
- Activation of radiator fan not OK
- High-pressure sender -G65 defective
- Radiator and/or condenser dirt-clogged
- Fault in refrigerant circuit
 
 
Measured value block 002
 
Display zone 1
 
Current valid compressor shut-off condition
 
Display zone 2
 
Last compressor shut-off condition
 
Display zone 3
 
Last-but-one compressor shut-off condition
 
Display zone 4
 
Last-but-two compressor shut-off condition
 
Breakdown of compressor shut-off conditions:
-   0   Compressor on (no shut-off condition detected)
-   1   Compressor off (pressure in refrigerant circuit was or is too high)
-   2   Compressor off (basic setting not performed)
-   3   Compressor off (pressure in refrigerant circuit is too low)
-   4   Compressor off (engine has been running for less than 5 sec.)
-   5   Compressor off (engine speed is below 300 rpm)
-   6   Compressor off (compressor switched off by ECON12   Compressor off (because of a request from the engine control unit)
- 13   Compressor off (because of a faulty signal from high-pressure sender G65)
- 14   Compressor off (because of a fault in the data bus system)
- 15   Compressor off (the pressure in the refrigerant circuit in this driving period was at least 30 times too high)
- 16   Compressor off (the measured temperature downstream of the evaporator has for over a minute been below 0?C)
- 17   Compressor off (the measured temperature downstream of the evaporator is below -5?C)
- 18   Compressor off (there is no valid measured value for the ambient temperature, e.g.: both sensors defective)
- 19   Compressor off (the engine is not running and the -J255 is in auxiliary heating mode)
- 20   Compressor off (no readout currently planned)
- 21   Compressor off (the automatic air recirculation function is set, the measured ambient temperature is between -8?C and 5?C, there is no request for air recirculation
- 22   Compressor off (the measured ambient temperature is between -8?C and 5?C, there is
a request for air recirculation but the measured temperature in the passenger compartment is below 8?C)
- 23   Compressor off (a fault in the radiator fans activation)
 
 
Measured value block 003
 
Display zone 1
 
Actual feedback value of recirculated air flap control motor potentiometer -G143 (in recirculated air flap control motor -V113)
 
Display zone 2
 
Specified feedback value for recirculated air flap control motor potentiometer -G143 (calculated by operating and display unit -J255)
J Display range 55...205
 
Display zone 3
 
Value of the recirculated air flap control motor potentiometer -G143 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (air recirculation flap closed, fresh air mode)
J Readout above 55 and below 95
 
Display zone 4
 
Value of the recirculated air flap control motor potentiometer -G143 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (air recirculation flap open)
J Readout above 165 and below 205
 
 
Measured value block 004
 
Display zone 1
 
Actual feedback value of air flow flap control motor potentiometer -G113 (in air flow flap control motor -V71)
 
Display zone 2
 
Specified feedback value for air flow flap control motor potentiometer -G113 (calculated by operating and display unit -J255)
J Display range 60...200
 
Display zone 3
 
Value of the air flow flap control motor potentiometer -G113 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (air flow/fresh air flaps closed, recirculated air mode)
J Readout above 60 and below 100
 
Display zone 4
 
Value of the air flow flap control motor potentiometer -G113 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (air flow/fresh air flaps open)
J Readout above 160 and below 200
 
 
Measured value block 005
Display zone 1
 
Actual feedback value of defroster flap control motor potentiometer -G135 (in defroster flap control motor -V107)
 
Display zone 2
 
Specified feedback value for defroster flap control motor potentiometer -G135 (calculated by operating and display unit -J255)
J Display range 70...195
 
Display zone 3
 
Value of the defroster flap control motor potentiometer -G135 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (defroster flap closed)
J Readout above 70 and below 110
 
Display zone 4
 
Value of the defroster flap control motor potentiometer -G135 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (defroster flap open)
J Readout above 155 and below 195
 
 
Measured value block 006
 
Display zone 1
 
Actual feedback value of front left defroster/chest vent shut-off flap control motor potentiometer -G318 (in front left defroster/chest vent shut-off flap control motor -V200)
 
Display zone 2
 
Specified feedback value for front left defroster/chest vent shut-off flap control motor potentiometer -G318 (calculated by operating and display unit -J255)
J Display range 10...250
 
Display zone 3
 
Value of the front left defroster/chest vent shut-off flap control motor potentiometer -G318 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (flap closed)
J Readout above 10 and below 50
 
Display zone 4
 
Value of the front left defroster/chest vent shut-off flap control motor potentiometer -G318 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (flap open)
J Readout above 210 and below 250
 
 
Measured value block 007
 
Display zone 1
 
Actual feedback value of front right defroster/chest vent shut-off flap control motor potentiometer -G317 (in front right defroster/chest vent shut-off flap control motor -V199)
 
Display zone 2
 
Specified feedback value for front right defroster/chest vent shut-off flap control motor potentiometer -G317 (calculated by operating and display unit -J255)
J Display range 5...250
 
Display zone 3
 
Value of the front right defroster/chest vent shut-off flap control motor potentiometer -G317 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (flap closed)
J Readout above 5 and below 45
 
Display zone 4
 
Value of the front right defroster/chest vent shut-off flap control motor potentiometer -G317 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (flap open)
J Readout above 200 and below 250
 
 
Measured value block 008
 
Display zone 1
 
Actual feedback value of left footwell flap control motor potentiometer -G139 (in left footwell flap control motor -V108)
 
Display zone 2
 
Specified feedback value for left footwell flap control motor potentiometer -G139 (calculated by operating and display unit -J255)
J Display range 5 ... 250
 
Display zone 3
 
Value of the left footwell flap control motor potentiometer -G139 with control motor set to lower stop determined during basic setting and stored in the operating and display unit -J255 (flap closed)
J Readout above 5 and below 50
 
Display zone 4
 
Value of the left footwell flap control motor potentiometer -G139 with control motor set to upper stop determined during basic setting and stored in the operating and display unit -J255 (flap open)
J Readout above 210 and below 250
 
 
Measured value block 009
 
Display zone 1
 
Actual feedback value of right footwell flap control motor potentiometer -G140 (in right footwell flap control motor -V109)
 
Display zone 2
 
Specified feedback value for right footwell flap control motor p...