INS TRU CTION M ANUAL
ATE 1/4 RACK
POWER SUPPLY
AUTOMATIC TEST EQUIPMENT
KEPCO INC.
An ISO 9001 Company.
MODEL
ATE 1/4 RACK
POWER SUPPLY
ORDER NO.
REV. NO.
NOTE
NOTES:
This on-line version of the Technical
IMPORTANT
Manual includes
associated serial numbers:
1)
This manual is valid for the following Model and
only installation and
operating instructions. For the complete
MODEL
SERIAL
REV. NO.
ATE 100-0.5M
F19688 NO.
9
manual, please contact Kepco.
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
3)
©1999, KEPCO, INC.
KEPCO
®
THE POWER SUPPLIER™
KEPCO, INC.
!
131-38 SANFORD AVENUE
!
FLUSHING, NY. 11352 U.S.A.
!
TEL (718) 461-7000
!
FAX (718) 767-1102
email: hq@kepcopower.com
!
World Wide Web: http://www.kepcopower.com
Declaration of Conformity
Application of Council directives:
73/23/EEC (LVD)
93/68/EEC (CE mark)
Standard to which Conformity is declared:
EN61 010-1 :1993
(Safety requirements for electrical equipment for measurement,
control and laboratory use)
Manufacturer's Name and Address:
Importer's Name and Address:
Type of Equipment:
Component Power Supply
Model No.:
[PRODUCT MODEL NUMBER]
Year of Manufacture:
I, the undersigned, declare that the product specified above, when used in conjunction with the condi-
tions of conformance set forth in the product instruction manual, complies with the requirements of the
Low Voltage Directive 73/23/EEC, which forms the basis for application of the CE Mark to this product.
Place:
KEPCO Inc.
131-38 Sanford Ave.
Flushing, N.Y.11352 USA
Saul Kupferberg
(Full Name)
Date:------
VP
OF SALES
(position)
228-1348 DC-COMP/INST 062399
A
Conditions of Conformance
When this product is used in applications governed by the requirements of the EEC, the following restric-
tions and conditions apply:
1.
For European 'pplications, requiring compliance to the Low Voltage Directive, 73/23/EEC, this power
supply is considered a component product, designed for "built in" applications. Because it is incom-
plete in construction, the end product enclosure must provide for compliance to any remaining electri-
cal safety requirements and act as a fire enclosure. (EN61010-1 Cl. 6, Cl. 7, CI.B, Cl. 9 and EN61010-
1 annex F)
This power supply is designed for stationary installation, with mains power applied via a detachable
power supply cord or via direct wiring to the source power terminal block.
This power supply is considered a Class 1 (earthed) product, and as such depends upon proper con-
nection to protective earth for safety from electric shock. (EN61 010-1 Cl. 6.5.4)
This power supply is intended for use as part of equipment meant for test, measurement and labora-
tory use, and is designed to operate from single phase, three wire power systems. This equipment
must be installed within a suitably wired equipment rack, utilizing a three wire (grounded) mains con-
nection. See wiring section of this manual for complete electrical wiring instructions. (EN61010-1 Cl.
6.5.4 and Cl.6.10.1)
This power supply has secondary output circuits that are considered hazardous, and which exceed
240 VA at a potential of 2V or more.
The output wiring terminals of this power supply has not been evaluated for field wiring and, therefore,
must be properly configured by the end product manufacturer prior to use.
This power supply employs a supplementary circuit protector in the form of a circuit breaker mounted
on the front panel. This circuit breaker protects the power supply itself from damage in the event of a
fault condition. For complete circuit protection of the end product, as well as the building wiring, it is
required that a primary circuit protection device be fitted to the branch circuit wiring. (EN61 01 0-1 Cl.
9.6.2)
Hazardous voltages are present within this power supply during normal operation. All operator adjust-
ments to the prcilduct are made via externally accessible switches, controls and signal lines as speci-
fied within the product operating instructions. There are no user or operator serviceable parts within
the product enclosure. Refer all servicing to qualified and trained Kepco service technicians.
2.
3.
4.
5.
6.
7.
8.
B
228-1351 COND/CONFORM 062399
1. Installation, Operation and Service Precautions
This product is designed for use in accordance with EN 61010-1 and UL 3101 for Installation Category 2,
Pollution Degree 2. Hazardous voltages are present within this product during normal operation. The
product should never be operated with the cover removed unless equivalent protection of the operator
from accidental contact with hazardous internal voltages is provided:
There are no operator seJViceable parts or adjustments within the product enclosure.
Refer all seJVicing to trained seJVice technician.
Source power must be removed from the product prior to performing any seJVicing.
This product is factory-wired for the nominal a-c mains voltage indicated on the rat-
ing nameplate located adjacent to the source power connection on the product's rear
panel. To reconfigure the product input for other nominal mains voltages as listed
herein, the product must be modified by a trained seJVice technician.
2. Grounding
This product is a Class 1 device which utilizes protective earthing to ensure operator safety.
The PROTECTIVE EARTHING CONDUCTOR TERMINAL must be properly con-
nected prior to application of source power to the product (see instructions on instal-
lation herein) in order to ensure safety from electric shock.
PROTECTIVE EARTHING CONDUCTOR TERMINAL- This symbol indicates the
point on the product to which the protective earthing conductor must be attached.
EARTH (GROUND) TERMINAL - This symbol is used to indicate a point which is
connected to the PROTECTIVE EARTHING TERMINAL. The component installer/
assembler must ensure that this point is connected to the PROTECTIVE EARTH-
ING TERMINAL.
CHASSIS TERMINAL -This symbol indicates frame (chassis) connection, which is
supplied as a point of convenience for performance purposes (see instructions on
grounding herein). This is not to be confused with the protective earthing point, and
may not be used in place of it.
3. Electric Shock Hazards
This product outputs hazardous voltage and energy levels as a function of normal operation. Operators
must be trained in its use and exercise caution as well as common sense during use to prevent accidental
shock.
This symbol appears adjacent to any external terminals at which hazardous voltage
levels as high as SOOV d-e may exist in the course of normal or single fault condi-
tions.
This symbol appears adjacent to any external terminals at which hazardous voltage
levels in excess of SOOV d-e may exist in the course of normal or single fault condi-
tions.
228-1352 SAFETY- (COVER REMOVAL) 062399
C/(0 BLANK)
TABLE OF CONTENTS
PARAGRAPH
PAGE
SECTION
I -
INSTRUCTION
1-1
1-3
1-9
1 -10
1-11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Scope of Manual . . . . . . .
General Description....
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Specifications, Electrical. . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Miscellaneous Featrues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5/1-6
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5/1-6
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5/1-6
1-12
SECTION II- INSTALLATION
2-1
2-3
24
2-6
2-8
2-10
2-13
2-14
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.2-1
Terminations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
A-C Input Reljurrcrnents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.2-4
Cooling .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.2-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Preliminary Check-Out.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Installation ..
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.2-5
Fast Mode Conversion of the ATE Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
SECTION Ill- OPERATION
3-1
3-3
3-6
3-12
3-16
3-19
3-21
3-24
3-27
3-29
3-31
3-34
3-37
3-41
345
3-51
3-57
3-60
3-64
3 70
3-77
3-75
3-78
3-84
3-91
394
]10]
3115
3 121
Gener·al ....
Safety Grounding
D-C Output Grounding ...
Power Supply/Load Interface
Load Connection, General. . .
. . . . . . . . . . . . 3-1
. . . . . . . . . . . . . . . . . . . 3-1
. . . . . . . . . . . . . . . . 3-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3
Load Connection, Method I (Local Error Sensing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Load Connection, Method II (Remote Error Sensing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4
Load Connections, Method Ill . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . . . . .
3-5
Standard Voltage Mode Operation (Front Panel Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5
. . . . . . . . . . . . . . . . . . . . . .3-6
Standard Current Mode Operation (Front Panel Control)
Overvoltage Crowbar, Setup and Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
Introduction to Remote Control of the ATE Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7
Programming the Voltage Control Channel .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7
Output Control with an External
0-10
Volt D-C Control Signal . . . . . . . . . . . . . . . . . . . . . . . .3-7
Voltage Control with a Two-Terminal Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8
Voltage Control with a High Impedance Control Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-10
Programming the Current Control Channel .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-12
Output Current Control with an External Control Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Output Current Control with a Two-Terminal Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
Programming the Overvoltage Protector.
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
3-15
R8rnote Crowbar Level Control with an
[xwrnal
0--10
Volt D-C
1
mA Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . . . . .
3-15
Automatic (Trackir1g) Control of the Crowbar Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-16
Programming Output Voltage and Output Current Simultaneously
. . . . . . . . . . . . . . . . . . . . . .
3-17
The USE-1 uf the "EXT. CURRENT COMPARISON AMPLIFIER"
for GenNal Feedback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Multirle Pow8r Supply and Systems Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
Sc:ries Operation of ATE Power Supplies.
. . . . . . . . . . . .
. . . . . . . . . . . . . . .
3-21
Parallf~l
Operation of ATE Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
. . . . . . . . . . . . . 3-32
Prowarnming With Reference
to
the NEGATIVE Power Supply Output ....
. . . . . . . . . . . . . . . . . 3-34
Application Df Isolated Flag Signals
ATE 1/4---2078