Checklist after service of class TD
LAB 2000, LAB 2000C, LAB 2002, LAB 4000, fP 3400 & fP 6400
Created by: Patrick Bergwall
Date: 2006-12-15
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
©
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16
Page 2 of 10
Index
1
2
INTRODUCTION............................................................................................................ 3
CHECK LIST CLASS TD............................................................................................... 3
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
©
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16
Page 3 of 10
1 Introduction
This checklist shall be used to make sure the amplifier is always checked in a proper way
after service has been done. It is important to follow the steps in this check list and check all
points so that the set up of parameters in the amplifier is correct adjusted. When have done all
checks and adjusted the parameters the amplifier will work properly and will have the output
power that it is designed for.
2 Check list class TD
Always clean the amplifier by blowing with compressed air through coolers and fans. Be
careful when blowing where big electrolytic capacitors are placed so that the capacitor doesn’t
get damaged.
If HF- or LF-units have been repaired, always turn the potentiometers fully counter clockwise
on HF-unit before starting the amplifier up (step 1).
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
©
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16
Page 4 of 10
1) After repair always start the amplifier with current potentiometer (VR3) in mains power
circuit. On is clockwise (cw) and off is counter clockwise (ccw). Check that the switch pulse
is normal. 300V line should increase some volts when relay clicks. Measure step 2 under start
up.
VR3
Measuring points.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
©
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16
Page 5 of 10
2) Measure that ±16V is correct balanced (tolerance ±0.2V). The voltage shall be balanced
from ±4.5V up to ±16V. If not stop immediately and turn the VR3 ccw again. Start
troubleshooting the amplifier.
Negative side.
Positive side.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
©
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Plik z chomika:
VSS33
Inne pliki z tego folderu:
FP10000Q_inside.jpg
(5886 KB)
023.jpg
(144 KB)
022.jpg
(96 KB)
AICO411.pdf
(1069 KB)
ACNC_ServMan_v02(1).pdf
(620 KB)
Inne foldery tego chomika:
1176
AB
Acoustasonic
Acoustic
ADA
Zgłoś jeśli
naruszono regulamin